x
Send Your Inquiry Today
Quick Quote
Water Tight Test System

Glove Watertight Test System

The most professional glove watertight test system, customized

Fengwang Glove Watertight Test System

The glove watertight test system is a classic glove production equipment for testing the quality of disposable gloves.Fengwang glove water lifting equipment (AQL – Acceptable Quality Level) can directly test the pinhole ratio of disposable gloves to determine the quality level of gloves.

Application of Watertight Testing Equipment for Gloves

The auto glove watertight test system is designed for disposable gloves such as nitrile, latex, PVC, or vinyl gloves. To test the AQL level of gloves, it is recommended that glove factories use a Fengwang watertight test machine for glove quality inspection, which is an important part of EN455-1:2020.

glove watertight test system

Fengwang Glove Watertight Test System Help Your Business

glove watertight test machine
The Features of Glove Watertight Test Machine

The glove watertight test system is suitable for automatically sorting and detecting pinholes and damages of PVC, nitrile, latex, and medical gloves.The features of glove watertight test machine are:

  1.  Accurate data
  2.  Easy to operate
  3.  Short detection time
  4.  Save labor
  5.  One person can operate multiple fixtures
  6.  Automatic sorting of qualified and unqualified gloves
  7.  Printable test result report
glove watertight test machine
How to Do Watertight Testing?

In this test, the glove manufacturer produced 10,000 gloves using the same materials, settings, and processes. Throughout the batch, 200 gloves will be randomly removed from the production line and tested on the glove watertight testing equipment. The test method is: each glove is filled with 1000 ml of water at room temperature, fixed on the cuff, and hung vertically for two minutes to check the pinholes. In order to achieve 2.5% AQL, no more than 10 gloves should be disqualified. If more than 10 gloves fail, the entire batch fails, and each glove must be inspected individually in the glove watertight testing machine, or the entire batch will be discarded. An AQL of 1.5% means that there are no more than 7 substandard gloves.

Glove Quality Test Method

EN455 is the European standard for the testing of medical gloves, and the first part of the EN455 standard, EN455-1:2020, regulates the problem of holes in medical gloves. Holes in gloves can expose healthcare workers and patients to harmful substances such as microbes and bodily fluids, leading to potential infection and cross-contamination.

To pass the EN455-1:2020 test, inspection gloves must have an acceptable quality level (AQL) of 1.5 or higher, and surgical gloves must have an acceptable quality level (AQL) of 0.65 or higher.

 

Send Your Inquiry Today
Quick Quote
Scroll to Top